Waterwise 9000 Use and Care Guide Page 5

  • Download
  • Add to my manuals
  • Print
  • Page
    / 12
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 4
PREPARING FOR FIRST TIME USE
Clean Collector/Dispenser Bottle
Ensure the dispensing valve (fig. B) is installed and tightened.
Fill bottle approximately three fourths full with warm tap water.
Add one or two drops of dish detergent.
DO NOT install filter cup at this time.
Seal bottle opening with cap.
Shake vigorously and drain.
Rinse thoroughly.
Add 6 ounces (180 ml) of 3 percent hydrogen peroxide to bottle.
Fill with warm tap or distilled water (less than 120°F).
DO NOT install the filter cup at this time.
Seal bottle opening with cap.
Shake vigorously and let stand for 20 minutes.
Drain and rinse thoroughly.
Sterilize and Rinse Carbon Filter Cup
Before installing, fully immerse new filter cup in distilled water for about
ve minutes. Then sterilize filter cup by fully immersing in boiling water
for about five minutes. Allow filter to cool before handling. Pour 1 to 2
cups distilled water through filter cup to rinse away any small, harmless
carbon fines (dust). Water draining from the filter cup may contain black
dust. This is typical. The carbon dust is formed as a result of production,
packaging and shipping of filter cup.
Install Filter Cup
Place sterilized filter cup into opening
of collector/dispenser bottle.
Replace Filter Cup
The filter cup should be replaced
every two months or after 60-80
gallons of water processed (which-
ever comes first). Replace more often
should the distilled water begin to
have an unwanted taste or odor.
Discard first gallon of distilled water
as it may contain small, harmless
carbon fines. Order replacement filters
from the outlet where you purchased
your distiller.
Waterwise 9000 Distiller Use & Care Guide 5
Collector/Dispenser Bottle
Figure B
Bottle Cap
Filter Cup
Dispensing
Valve
Page view 4
1 2 3 4 5 6 7 8 9 10 11 12

Comments to this Manuals